Motion-robust free-running volumetric cardiovascular MRI

Read original: arXiv:2308.02088 - Published 6/25/2024 by Syed M. Arshad, Lee C. Potter, Chong Chen, Yingmin Liu, Preethi Chandrasekaran, Christopher Crabtree, Matthew S. Tong, Orlando P. Simonetti, Yuchi Han, Rizwan Ahmad
Total Score

0

🎯

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • Presents a new method called "compressive recovery with outlier rejection" (CORe) to improve the robustness of free-running volumetric cardiovascular MRI (CMR) to motion artifacts
  • Compares CORe to traditional compressed sensing (CS), robust regression (RR), and an existing outlier rejection method using simulations and real-world CMR datasets
  • Demonstrates that CORe can effectively suppress motion artifacts while maintaining or improving image quality and flow measurement reliability

Plain English Explanation

Cardiovascular MRI (CMR) is a powerful technique for imaging the heart and blood flow, but it can be sensitive to patient motion during the scanning process. This paper introduces a new method called "compressive recovery with outlier rejection" (CORe) that aims to make free-running volumetric CMR more robust to motion artifacts.

The key idea behind CORe is to model the motion-related outliers in the measured MRI data as a separate component that can be jointly estimated along with the underlying image. By enforcing the MR physics-guided "group sparsity" on this outlier component, CORe is able to effectively identify and suppress the motion artifacts while preserving the overall image quality.

Through extensive simulations and evaluations on real-world CMR datasets, the researchers demonstrate that CORe outperforms traditional compressed sensing (CS), robust regression (RR), and an existing outlier rejection method in terms of both image quality metrics and expert reader assessments. Particularly for 4D flow imaging, which captures the complex blood flow dynamics, CORe is shown to yield more reliable and consistent measurements, even in the presence of involuntary subject motion or exercise stress.

This work represents an important advancement in motion-robust CMR imaging, which has broad implications for improving the clinical utility and accessibility of this technology. By making CMR more resilient to patient motion, CORe can help enable wider adoption of free-running volumetric CMR techniques in both research and clinical settings.

Technical Explanation

The proposed CORe method models the motion-related outliers in the measured MRI data as an additive auxiliary variable. This auxiliary variable is then constrained using a "group sparsity" regularization term that enforces the MR physics-guided structure of the outliers.

The CORe algorithm jointly estimates the underlying image and the outlier component through an iterative optimization process. This approach allows CORe to effectively identify and suppress the motion artifacts while preserving the overall image quality.

The researchers evaluate CORe using two simulation studies and three real-world CMR datasets: 3D cine, 4D flow at rest, and 4D flow under stress. The simulation studies compare CORe to traditional CS, RR, and an existing outlier rejection method, demonstrating that CORe outperforms these baselines in terms of normalized mean square error and structural similarity index.

For the real-world 3D cine datasets, expert readers found that CORe was more effective in suppressing motion artifacts while maintaining or improving image sharpness compared to traditional CS. The 4D flow datasets further showed that CORe yields more reliable and consistent flow measurements, especially in the presence of involuntary subject motion or exercise stress.

Critical Analysis

The paper provides a comprehensive evaluation of the CORe method, using both simulations and real-world CMR datasets. The results demonstrate the effectiveness of CORe in suppressing motion artifacts and preserving image quality and flow measurement reliability.

However, the paper does not extensively discuss the limitations of the proposed method. For example, it is unclear how CORe would perform in the presence of more severe or complex motion patterns, or how the method's performance might vary across different patient populations or imaging protocols.

Additionally, while the authors provide implementation code and datasets on GitHub, the lack of a detailed description of the CORe algorithm in the paper may make it challenging for other researchers to fully understand and reproduce the method. A more thorough technical explanation, including the mathematical formulation and the iterative optimization procedure, would be beneficial for the broader research community.

Overall, the CORe method represents an important contribution to the field of motion-robust CMR imaging. Further research exploring the method's limitations and potential extensions could help solidify its place as a valuable tool for improving the clinical utility of free-running volumetric CMR techniques.

Conclusion

This paper presents a novel outlier mitigation method called "compressive recovery with outlier rejection" (CORe) that can significantly improve the robustness of free-running volumetric cardiovascular MRI (CMR) to motion artifacts. Through extensive simulations and evaluations on real-world CMR datasets, the researchers demonstrate that CORe outperforms traditional compressed sensing, robust regression, and an existing outlier rejection method in terms of both image quality and flow measurement reliability.

The CORe method's ability to effectively suppress motion-related artifacts while preserving overall image quality and flow data integrity has important implications for the wider adoption and clinical utility of free-running volumetric CMR techniques. By making CMR more resilient to patient motion, this work represents a significant advancement in the field and could help enable more accessible and reliable cardiovascular imaging for research and clinical applications.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

🎯

Total Score

0

Motion-robust free-running volumetric cardiovascular MRI

Syed M. Arshad, Lee C. Potter, Chong Chen, Yingmin Liu, Preethi Chandrasekaran, Christopher Crabtree, Matthew S. Tong, Orlando P. Simonetti, Yuchi Han, Rizwan Ahmad

PURPOSE: To present and assess an outlier mitigation method that makes free-running volumetric cardiovascular MRI (CMR) more robust to motion. METHODS: The proposed method, called compressive recovery with outlier rejection (CORe), models outliers in the measured data as an additive auxiliary variable. We enforce MR physics-guided group sparsity on the auxiliary variable, and jointly estimate it along with the image using an iterative algorithm. For evaluation, CORe is first compared to traditional compressed sensing (CS), robust regression (RR), and an existing outlier rejection method using two simulation studies. Then, CORe is compared to CS using seven three-dimensional (3D) cine, 12 rest four-dimensional (4D) flow, and eight stress 4D flow imaging datasets. RESULTS: Our simulation studies show that CORe outperforms CS, RR, and the existing outlier rejection method in terms of normalized mean square error and structural similarity index across 55 different realizations. The expert reader evaluation of 3D cine images demonstrates that CORe is more effective in suppressing artifacts while maintaining or improving image sharpness. Finally, 4D flow images show that CORe yields more reliable and consistent flow measurements, especially in the presence of involuntary subject motion or exercise stress. CONCLUSION: An outlier rejection method is presented and tested using simulated and measured data. This method can help suppress motion artifacts in a wide range of free-running CMR applications. CODE & DATA: Implementation code and datasets are available on GitHub at http://github.com/OSU-MR/motion-robust-CMR

Read more

6/25/2024

🔄

Total Score

0

Motion-compensated MR CINE reconstruction with reconstruction-driven motion estimation

Jiazhen Pan, Wenqi Huang, Daniel Rueckert, Thomas Kustner, Kerstin Hammernik

In cardiac CINE, motion-compensated MR reconstruction (MCMR) is an effective approach to address highly undersampled acquisitions by incorporating motion information between frames. In this work, we propose a novel perspective for addressing the MCMR problem and a more integrated and efficient solution to the MCMR field. Contrary to state-of-the-art (SOTA) MCMR methods which break the original problem into two sub-optimization problems, i.e. motion estimation and reconstruction, we formulate this problem as a single entity with one single optimization. Our approach is unique in that the motion estimation is directly driven by the ultimate goal, reconstruction, but not by the canonical motion-warping loss (similarity measurement between motion-warped images and target images). We align the objectives of motion estimation and reconstruction, eliminating the drawbacks of artifacts-affected motion estimation and therefore error-propagated reconstruction. Further, we can deliver high-quality reconstruction and realistic motion without applying any regularization/smoothness loss terms, circumventing the non-trivial weighting factor tuning. We evaluate our method on two datasets: 1) an in-house acquired 2D CINE dataset for the retrospective study and 2) the public OCMR cardiac dataset for the prospective study. The conducted experiments indicate that the proposed MCMR framework can deliver artifact-free motion estimation and high-quality MR images even for imaging accelerations up to 20x, outperforming SOTA non-MCMR and MCMR methods in both qualitative and quantitative evaluation across all experiments. The code is available at https://github.com/JZPeterPan/MCMR-Recon-Driven-Motion.

Read more

8/19/2024

Accelerated Real-time Cine and Flow under In-magnet Staged Exercise
Total Score

0

Accelerated Real-time Cine and Flow under In-magnet Staged Exercise

Preethi Chandrasekaran, Chong Chen, Yingmin Liu, Syed Murtaza Arshad, Christopher Crabtree, Matthew Tong, Yuchi Han, Rizwan Ahmad

Background: Cardiovascular magnetic resonance imaging (CMR) is a wellestablished imaging tool for diagnosing and managing cardiac conditions. The integration of exercise stress with CMR (ExCMR) can enhance its diagnostic capacity. Despite recent advances in CMR technology, quantitative ExCMR during exercise remains technically challenging due to motion artifacts and limited spatial and temporal resolution. Methods: This study investigated the feasibility of biventricular functional and hemodynamic assessment using real-time (RT) ExCMR during a staged exercise protocol in 24 healthy volunteers. We applied a coil reweighting technique and employed high acceleration rates to minimize motion blurring and artifacts. We further applied a beat-selection technique that identified beats from the endexpiratory phase to minimize the impact of respiration-induced through-plane motion. Additionally, results from six patients were presented to demonstrate clinical feasibility. Results: Our findings indicated a consistent decrease in end-systolic volume and stable end-diastolic volume across exercise intensities, leading to increased stroke volume and ejection fraction. The selection of end-expiratory beats enhanced the repeatability of cardiac function parameters, as shown by scan-rescan tests in nine volunteers. High scores from a blinded image quality assessment indicated that coil reweighting effectively minimized motion artifacts. Conclusions: This study demonstrated the feasibility of RT ExCMR with inmagnet exercise in healthy subjects and patients. Our results indicate that high acceleration rates, coil reweighting, and selection of respiratory phase-specific heartbeats enhance image quality and repeatability of quantitative RT ExCMR.

Read more

5/24/2024

🖼️

Total Score

0

Low-rank based motion correction followed by automatic frame selection in DT-CMR

Fanwen Wang, Pedro F. Ferreira, Camila Munoz, Ke Wen, Yaqing Luo, Jiahao Huang, Yinzhe Wu, Dudley J. Pennell, Andrew D. Scott, Sonia Nielles-Vallespin, Guang Yang

Motivation: Post-processing of in-vivo diffusion tensor CMR (DT-CMR) is challenging due to the low SNR and variation in contrast between frames which makes image registration difficult, and the need to manually reject frames corrupted by motion. Goals: To develop a semi-automatic post-processing pipeline for robust DT-CMR registration and automatic frame selection. Approach: We used low intrinsic rank averaged frames as the reference to register other low-ranked frames. A myocardium-guided frame selection rejected the frames with signal loss, through-plane motion and poor registration. Results: The proposed method outperformed our previous noise-robust rigid registration on helix angle data quality and reduced negative eigenvalues in healthy volunteers.

Read more

6/21/2024