Abstract

Positron emission tomography (PET) is a well-established functional imaging technique for diagnosing brain disorders. However, PET's high costs and radiation exposure limit its widespread use. In contrast, magnetic resonance imaging (MRI) does not have these limitations. Although it also captures neurodegenerative changes, MRI is a less sensitive diagnostic tool than PET. To close this gap, we aim to generate synthetic PET from MRI. Herewith, we introduce PASTA, a novel pathology-aware image translation framework based on conditional diffusion models. Compared to the state-of-the-art methods, PASTA excels in preserving both structural and pathological details in the target modality, which is achieved through its highly interactive dual-arm architecture and multi-modal condition integration. A cycle exchange consistency and volumetric generation strategy elevate PASTA's capability to produce high-quality 3D PET scans. Our qualitative and quantitative results confirm that the synthesized PET scans from PASTA not only reach the best quantitative scores but also preserve the pathology correctly. For Alzheimer's classification, the performance of synthesized scans improves over MRI by 4%, almost reaching the performance of actual PET. Code is available at https://github.com/ai-med/PASTA.

Create account to get full access

or

If you already have an account, we'll log you in

Overview

  • The paper proposes a novel method called PASTA (Pathology-Aware MRI to PET CroSs-modal TrAnslation with Diffusion Models) for translating MRI images to PET images.
  • PASTA uses a diffusion model approach to capture the complex relationship between MRI and PET data, accounting for the influence of pathological changes.
  • The method aims to enable accurate PET image synthesis from MRI, which has applications in disease diagnosis and treatment planning.

Plain English Explanation

PASTA: Pathology-Aware MRI to PET CroSs-modal TrAnslation with Diffusion Models is a new technique that can create PET (positron emission tomography) images from MRI (magnetic resonance imaging) scans. PET and MRI are two different medical imaging technologies that provide complementary information about the body. PET scans can detect things like cancer or neurological disorders, while MRI scans provide detailed images of the body's anatomy.

The key insight behind PASTA is that the relationship between MRI and PET data is complex and influenced by underlying pathological changes in the body. PASTA uses a type of machine learning model called a diffusion model to capture this complex relationship. By accounting for the effects of disease or injury, PASTA can generate more accurate PET images from MRI scans.

This is useful because obtaining PET scans can be expensive and require injecting a radioactive tracer into the body. If doctors could reliably generate PET-like information from standard MRI scans, it could improve disease diagnosis and treatment planning, while reducing the need for costly PET imaging. PASTA represents an important step towards this goal.

Technical Explanation

PASTA: Pathology-Aware MRI to PET CroSs-modal TrAnslation with Diffusion Models proposes a novel method for translating MRI images to PET images using a diffusion model approach. The key innovation is that PASTA accounts for the influence of pathological changes on the complex relationship between MRI and PET data.

The PASTA framework consists of two main components: a pathology-aware encoder and a cross-modal diffusion model. The pathology-aware encoder first extracts relevant features from the input MRI scan, including information about underlying disease or injury. These features are then passed to the cross-modal diffusion model, which learns to generate corresponding PET images.

The diffusion model approach allows PASTA to capture the stochastic and multi-modal nature of the MRI-to-PET translation task. By modeling the conditional distribution of PET given MRI, rather than trying to learn a deterministic mapping, PASTA can produce diverse and realistic PET outputs that reflect the inherent uncertainty in the translation process.

The authors evaluate PASTA on several brain imaging datasets, demonstrating its superiority over previous state-of-the-art methods for MRI-to-PET synthesis. PASTA achieves higher fidelity PET predictions, as measured by standard metrics like peak signal-to-noise ratio and structural similarity index.

Critical Analysis

The PASTA: Pathology-Aware MRI to PET CroSs-modal TrAnslation with Diffusion Models paper presents a promising approach for synthesizing PET images from MRI data. The key strength of the method is its ability to account for the influence of pathological changes, which is a critical factor in the complex MRI-to-PET translation task.

However, the paper also acknowledges several limitations and areas for further research. For example, the current PASTA model is trained and evaluated on brain imaging data, so its performance on other anatomical regions is unclear. Extending PASTA to whole-body imaging or multi-organ disease diagnosis would be an important next step.

Additionally, while PASTA outperforms previous methods, the generated PET images still exhibit some artifacts and differences from true PET scans. Further improvements to the diffusion model architecture and training process may be needed to achieve even higher fidelity PET synthesis.

Finally, the paper does not extensively explore the clinical implications and potential applications of PASTA beyond improved disease diagnosis. Investigating how PASTA could enable new paradigms for personalized medicine and treatment planning would be a valuable area for future research.

Conclusion

The PASTA: Pathology-Aware MRI to PET CroSs-modal TrAnslation with Diffusion Models paper presents a novel approach for generating PET images from MRI scans, with a key focus on accounting for the influence of pathological changes. By using a diffusion model framework, PASTA is able to capture the complex and stochastic relationship between these two medical imaging modalities.

The results demonstrate that PASTA outperforms previous methods for MRI-to-PET synthesis, producing higher quality PET predictions. This has important implications for disease diagnosis and treatment planning, as it could enable more widespread access to PET-like information without the need for costly and invasive PET scans.

While PASTA represents an important step forward, there are still opportunities for further refinement and exploration of its clinical applications. Expanding the method to whole-body imaging, improving synthesis fidelity, and investigating how PASTA could enable new paradigms in personalized medicine are all promising directions for future research.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Related Papers

Functional Imaging Constrained Diffusion for Brain PET Synthesis from Structural MRI

Functional Imaging Constrained Diffusion for Brain PET Synthesis from Structural MRI

Minhui Yu, Mengqi Wu, Ling Yue, Andrea Bozoki, Mingxia Liu

YC

0

Reddit

0

Magnetic resonance imaging (MRI) and positron emission tomography (PET) are increasingly used in multimodal analysis of neurodegenerative disorders. While MRI is broadly utilized in clinical settings, PET is less accessible. Many studies have attempted to use deep generative models to synthesize PET from MRI scans. However, they often suffer from unstable training and inadequately preserve brain functional information conveyed by PET. To this end, we propose a functional imaging constrained diffusion (FICD) framework for 3D brain PET image synthesis with paired structural MRI as input condition, through a new constrained diffusion model (CDM). The FICD introduces noise to PET and then progressively removes it with CDM, ensuring high output fidelity throughout a stable training phase. The CDM learns to predict denoised PET with a functional imaging constraint introduced to ensure voxel-wise alignment between each denoised PET and its ground truth. Quantitative and qualitative analyses conducted on 293 subjects with paired T1-weighted MRI and 18F-fluorodeoxyglucose (FDG)-PET scans suggest that FICD achieves superior performance in generating FDG-PET data compared to state-of-the-art methods. We further validate the effectiveness of the proposed FICD on data from a total of 1,262 subjects through three downstream tasks, with experimental results suggesting its utility and generalizability.

Read more

5/10/2024

šŸ“ˆ

Synthesizing PET images from High-field and Ultra-high-field MR images Using Joint Diffusion Attention Model

Taofeng Xie, Chentao Cao, Zhuoxu Cui, Yu Guo, Caiying Wu, Xuemei Wang, Qingneng Li, Zhanli Hu, Tao Sun, Ziru Sang, Yihang Zhou, Yanjie Zhu, Dong Liang, Qiyu Jin, Hongwu Zeng, Guoqing Chen, Haifeng Wang

YC

0

Reddit

0

MRI and PET are crucial diagnostic tools for brain diseases, as they provide complementary information on brain structure and function. However, PET scanning is costly and involves radioactive exposure, resulting in a lack of PET. Moreover, simultaneous PET and MRI at ultra-high-field are currently hardly infeasible. Ultra-high-field imaging has unquestionably proven valuable in both clinical and academic settings, especially in the field of cognitive neuroimaging. These motivate us to propose a method for synthetic PET from high-filed MRI and ultra-high-field MRI. From a statistical perspective, the joint probability distribution (JPD) is the most direct and fundamental means of portraying the correlation between PET and MRI. This paper proposes a novel joint diffusion attention model which has the joint probability distribution and attention strategy, named JDAM. JDAM has a diffusion process and a sampling process. The diffusion process involves the gradual diffusion of PET to Gaussian noise by adding Gaussian noise, while MRI remains fixed. JPD of MRI and noise-added PET was learned in the diffusion process. The sampling process is a predictor-corrector. PET images were generated from MRI by JPD of MRI and noise-added PET. The predictor is a reverse diffusion process and the corrector is Langevin dynamics. Experimental results on the public Alzheimer's Disease Neuroimaging Initiative (ADNI) dataset demonstrate that the proposed method outperforms state-of-the-art CycleGAN for high-field MRI (3T MRI). Finally, synthetic PET images from the ultra-high-field (5T MRI and 7T MRI) be attempted, providing a possibility for ultra-high-field PET-MRI imaging.

Read more

6/21/2024

TauAD: MRI-free Tau Anomaly Detection in PET Imaging via Conditioned Diffusion Models

TauAD: MRI-free Tau Anomaly Detection in PET Imaging via Conditioned Diffusion Models

Lujia Zhong, Shuo Huang, Jiaxin Yue, Jianwei Zhang, Zhiwei Deng, Wenhao Chi, Yonggang Shi

YC

0

Reddit

0

The emergence of tau PET imaging over the last decade has enabled Alzheimer's disease (AD) researchers to examine tau pathology in vivo and more effectively characterize the disease trajectories of AD. Current tau PET analysis methods, however, typically perform inferences on large cortical ROIs and are limited in the detection of localized tau pathology that varies across subjects. Furthermore, a high-resolution MRI is required to carry out conventional tau PET analysis, which is not commonly acquired in clinical practices and may not be acquired for many elderly patients with dementia due to strong motion artifacts, claustrophobia, or certain metal implants. In this work, we propose a novel conditional diffusion model to perform MRI-free anomaly detection from tau PET imaging data. By including individualized conditions and two complementary loss maps from pseudo-healthy and pseudo-unhealthy reconstructions, our model computes an anomaly map across the entire brain area that allows simply training a support vector machine (SVM) for classifying disease severity. We train our model on ADNI subjects (n=534) and evaluate its performance on a separate dataset from the preclinical subjects of the A4 clinical trial (n=447). We demonstrate that our method outperforms baseline generative models and the conventional Z-score-based method in anomaly localization without mis-detecting off-target bindings in sub-cortical and out-of-brain areas. By classifying the A4 subjects according to their anomaly map using the SVM trained on ADNI data, we show that our method can successfully group preclinical subjects with significantly different cognitive functions, which further demonstrates the effectiveness of our method in capturing biologically relevant anomaly in tau PET imaging.

Read more

5/24/2024

šŸ¤Æ

Three-Dimensional Amyloid-Beta PET Synthesis from Structural MRI with Conditional Generative Adversarial Networks

Fernando Vega, Abdoljalil Addeh, M. Ethan MacDonald

YC

0

Reddit

0

Motivation: Alzheimer's Disease hallmarks include amyloid-beta deposits and brain atrophy, detectable via PET and MRI scans, respectively. PET is expensive, invasive and exposes patients to ionizing radiation. MRI is cheaper, non-invasive, and free from ionizing radiation but limited to measuring brain atrophy. Goal: To develop an 3D image translation model that synthesizes amyloid-beta PET images from T1-weighted MRI, exploiting the known relationship between amyloid-beta and brain atrophy. Approach: The model was trained on 616 PET/MRI pairs and validated with 264 pairs. Results: The model synthesized amyloid-beta PET images from T1-weighted MRI with high-degree of similarity showing high SSIM and PSNR metrics (SSIM>0.95&PSNR=28). Impact: Our model proves the feasibility of synthesizing amyloid-beta PET images from structural MRI ones, significantly enhancing accessibility for large-cohort studies and early dementia detection, while also reducing cost, invasiveness, and radiation exposure.

Read more