Retinal arterial blood flow measured by real-time Doppler holography at 33,000 frames per second

Read original: arXiv:2409.17180 - Published 9/27/2024 by Yann Fischer, Zacharie Auray, Olivier Martinache, Marius Dubosc, No'e Top'eza, Chlo'e Magnier, Maxime Boy-Arnould, Michael Atlan
Total Score

0

⛏️

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • The study presents a new method for measuring total retinal arterial blood flow using real-time Doppler holography.
  • This technique allows for non-invasive, high-speed imaging of the retinal blood flow.
  • The analysis involves segmenting the retinal arteries and calculating blood velocity using Doppler frequency changes.
  • The findings suggest that Doppler holography could be a valuable tool for diagnosing and monitoring retinal vascular conditions.

Plain English Explanation

The researchers have developed a new way to measure the total amount of blood flowing through the arteries in the retina [retinal arterial blood flow]. They used a technique called Doppler holography, which can take images of the retina very quickly - 33,000 frames per second. This allows them to see the blood flowing through the retinal arteries in real-time.

To measure the blood flow, the researchers first identified the main arteries in the retina [segmenting primary in-plane retinal arteries]. They then calculated how fast the blood is moving in these arteries by looking at changes in the Doppler frequency [calculating local blood velocity using Doppler frequency broadening]. The Doppler frequency changes as the blood moves, and the researchers used a mathematical model to translate these changes into actual blood flow measurements.

The researchers believe this new Doppler holography technique could be very useful for diagnosing and tracking the treatment of conditions that affect the blood vessels in the retina [retinal vascular conditions]. It provides more detailed information about blood flow than existing imaging methods, which could help doctors better understand and manage these types of eye problems.

Technical Explanation

The study describes a novel quantitative estimation method for measuring [quantitative estimation method] the total blood flow through the arteries in the retina [total retinal arterial blood flow]. The key innovation is the use of real-time Doppler holography, a high-speed imaging technique that can capture retinal images at an unprecedented rate of 33,000 frames per second [real-time Doppler holography at an unprecedented frame rate of 33,000 frames per second].

This high-speed imaging allows for non-invasive angiographic [non-invasive angiographic imaging] visualization of the retinal blood flow, providing detailed information about blood flow patterns that is essential for assessing retinal health [detailed blood flow contrasts essential for assessing retinal health].

The analysis method involves first segmenting the primary arteries within the retinal plane [segmenting primary in-plane retinal arteries]. The researchers then calculate the local blood velocity in these arteries by analyzing the Doppler frequency broadening [calculating local blood velocity using Doppler frequency broadening]. To convert the Doppler measurements into quantitative blood flow estimates, the analysis incorporates a forward scattering model [forward scattering model to achieve blood flow estimation].

The key finding is that this Doppler holography technique shows significant potential as a powerful diagnostic tool for retinal vascular conditions [potential of Doppler holography as a powerful tool for diagnosing and monitoring the treatment of retinal vascular conditions], complementing existing imaging methods currently used in clinical practice.

Critical Analysis

The paper provides a thorough technical description of the Doppler holography imaging method and the quantitative analysis approach used to estimate retinal arterial blood flow. The high frame rate of 33,000 fps represents a notable technical advancement, enabling real-time visualization of retinal blood flow dynamics.

However, the study is limited to a relatively small sample size, and further validation would be needed to demonstrate the reliability and accuracy of the blood flow measurements across a broader patient population. Additionally, the paper does not address potential challenges around patient compliance or motion artifacts that could impact the quality of the imaging data.

While the researchers highlight the potential clinical utility of this technique, more work is needed to directly compare its performance to established retinal imaging methods, such as fluorescein angiography or optical coherence tomography angiography. Demonstrating improved diagnostic capabilities or the ability to monitor treatment response would strengthen the case for adopting this new Doppler holography approach in routine clinical practice.

Overall, the study presents an innovative technical solution for quantifying retinal blood flow, but additional research is required to fully validate the method and explore its real-world applications in the diagnosis and management of retinal vascular diseases.

Conclusion

This study introduces a novel quantitative estimation method for measuring total retinal arterial blood flow using high-speed Doppler holography imaging. The technique enables non-invasive, high-frame-rate visualization of retinal blood flow, providing detailed information that could be valuable for assessing and monitoring retinal vascular health.

The researchers demonstrate a robust analysis pipeline for segmenting retinal arteries and calculating local blood velocities, which can then be integrated into a forward scattering model to derive quantitative blood flow estimates. The findings suggest that this Doppler holography approach has significant potential as a diagnostic and monitoring tool for retinal vascular conditions, complementing existing imaging modalities.

While further research is needed to validate the method and explore its real-world clinical applications, this study represents an important advancement in the field of retinal blood flow imaging and analysis. The ability to non-invasively measure total arterial blood flow could lead to improved understanding, diagnosis, and treatment of a range of retinal vascular disorders.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

⛏️

Total Score

0

New!Retinal arterial blood flow measured by real-time Doppler holography at 33,000 frames per second

Yann Fischer, Zacharie Auray, Olivier Martinache, Marius Dubosc, No'e Top'eza, Chlo'e Magnier, Maxime Boy-Arnould, Michael Atlan

This study presents a novel quantitative estimation method for total retinal arterial blood flow utilizing real-time Doppler holography at an unprecedented frame rate of 33,000 frames per second. This technique, leveraging high-speed digital holography, enables non-invasive angiographic imaging of the retina, providing detailed blood flow contrasts essential for assessing retinal health. The proposed quantitative analysis method consists of segmenting primary in-plane retinal arteries and calculating local blood velocity using Doppler frequency broadening. The analysis integrates a forward scattering model to achieve blood flow estimation. Our findings highlight the potential of Doppler holography as a powerful tool for diagnosing and monitoring the treatment of retinal vascular conditions, complementary to existing imaging methods.

Read more

9/27/2024

Phase-shifted remote photoplethysmography for estimating heart rate and blood pressure from facial video
Total Score

0

Phase-shifted remote photoplethysmography for estimating heart rate and blood pressure from facial video

Gyutae Hwang, Sang Jun Lee

Human health can be critically affected by cardiovascular diseases, such as hypertension, arrhythmias, and stroke. Heart rate and blood pressure are important biometric information for the monitoring of cardiovascular system and early diagnosis of cardiovascular diseases. Existing methods for estimating the heart rate are based on electrocardiography and photoplethyomography, which require contacting the sensor to the skin surface. Moreover, catheter and cuff-based methods for measuring blood pressure cause inconvenience and have limited applicability. Therefore, in this thesis, we propose a vision-based method for estimating the heart rate and blood pressure. This thesis proposes a 2-stage deep learning framework consisting of a dual remote photoplethysmography network (DRP-Net) and bounded blood pressure network (BBP-Net). In the first stage, DRP-Net infers remote photoplethysmography (rPPG) signals for the acral and facial regions, and these phase-shifted rPPG signals are utilized to estimate the heart rate. In the second stage, BBP-Net integrates temporal features and analyzes phase discrepancy between the acral and facial rPPG signals to estimate SBP and DBP values. To improve the accuracy of estimating the heart rate, we employed a data augmentation method based on a frame interpolation model. Moreover, we designed BBP-Net to infer blood pressure within a predefined range by incorporating a scaled sigmoid function. Our method resulted in estimating the heart rate with the mean absolute error (MAE) of 1.78 BPM, reducing the MAE by 34.31 % compared to the recent method, on the MMSE-HR dataset. The MAE for estimating the systolic blood pressure (SBP) and diastolic blood pressure (DBP) were 10.19 mmHg and 7.09 mmHg. On the V4V dataset, the MAE for the heart rate, SBP, and DBP were 3.83 BPM, 13.64 mmHg, and 9.4 mmHg, respectively.

Read more

8/27/2024

MEMO: Dataset and Methods for Robust Multimodal Retinal Image Registration with Large or Small Vessel Density Differences
Total Score

0

MEMO: Dataset and Methods for Robust Multimodal Retinal Image Registration with Large or Small Vessel Density Differences

Chiao-Yi Wang, Faranguisse Kakhi Sadrieh, Yi-Ting Shen, Shih-En Chen, Sarah Kim, Victoria Chen, Achyut Raghavendra, Dongyi Wang, Osamah Saeedi, Yang Tao

The measurement of retinal blood flow (RBF) in capillaries can provide a powerful biomarker for the early diagnosis and treatment of ocular diseases. However, no single modality can determine capillary flowrates with high precision. Combining erythrocyte-mediated angiography (EMA) with optical coherence tomography angiography (OCTA) has the potential to achieve this goal, as EMA can measure the absolute 2D RBF of retinal microvasculature and OCTA can provide the 3D structural images of capillaries. However, multimodal retinal image registration between these two modalities remains largely unexplored. To fill this gap, we establish MEMO, the first public multimodal EMA and OCTA retinal image dataset. A unique challenge in multimodal retinal image registration between these modalities is the relatively large difference in vessel density (VD). To address this challenge, we propose a segmentation-based deep-learning framework (VDD-Reg) and a new evaluation metric (MSD), which provide robust results despite differences in vessel density. VDD-Reg consists of a vessel segmentation module and a registration module. To train the vessel segmentation module, we further designed a two-stage semi-supervised learning framework (LVD-Seg) combining supervised and unsupervised losses. We demonstrate that VDD-Reg outperforms baseline methods quantitatively and qualitatively for cases of both small VD differences (using the CF-FA dataset) and large VD differences (using our MEMO dataset). Moreover, VDD-Reg requires as few as three annotated vessel segmentation masks to maintain its accuracy, demonstrating its feasibility.

Read more

7/16/2024

👨‍🏫

Total Score

0

Correlating Stroke Risk with Non-Invasive Tracing of Brain Blood Dynamic via a Portable Speckle Contrast Optical Spectroscopy Laser Device

Yu Xi Huang, Simon Mahler, Aidin Abedi, Julian Michael Tyszka, Yu Tung Lo, Patrick D. Lyden, Jonathan Russin, Charles Liu, Changhuei Yang

Stroke poses a significant global health threat, with millions affected annually, leading to substantial morbidity and mortality. Current stroke risk assessment for the general population relies on markers such as demographics, blood tests, and comorbidities. A minimally invasive, clinically scalable, and cost-effective way to directly measure cerebral blood flow presents an opportunity. This opportunity has potential to positively impact effective stroke risk assessment prevention and intervention. Physiological changes in the cerebral vascular system, particularly in response to carbon dioxide level changes and oxygen deprivation, such as during breath-holding, can offer insights into stroke risk assessment. However, existing methods for measuring cerebral perfusion reserve, such as blood flow and blood volume changes, are limited by either invasiveness or impracticality. Here, we propose a transcranial approach using speckle contrast optical spectroscopy (SCOS) to non-invasively monitor regional changes in brain blood flow and volume during breath-holding. Our study, conducted on 50 individuals classified into two groups (low-risk and higher-risk for stroke), shows significant differences in blood dynamic changes during breath-holding between the two groups, providing physiological insights for stroke risk assessment using a non-invasive quantification paradigm. Given its cost-effectiveness, scalability, portability, and simplicity, this laser-centric tool has significant potential in enhancing the pre-screening of stroke and mitigating strokes in the general population through early diagnosis and intervention.

Read more

7/24/2024