Noncontact Respiratory Anomaly Detection Using Infrared Light-Wave Sensing

Read original: arXiv:2301.03713 - Published 4/17/2024 by Md Zobaer Islam, Brenden Martin, Carly Gotcher, Tyler Martinez, John F. O'Hara, Sabit Ekin
Total Score

0

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • Monitoring human breathing patterns is important for understanding physical and psychological states
  • Abnormal breathing can indicate serious health issues, requiring further diagnosis and treatment
  • Wireless light-wave sensing (LWS) using infrared light shows promise for safe, discreet, and non-invasive breathing monitoring without privacy concerns
  • The respiration monitoring system needs to be trained on different breathing patterns to identify anomalies
  • The system must also validate collected data as a breathing waveform, discarding faulty data caused by external interruptions, user movement, or system issues

Plain English Explanation

Breathing is an essential function that provides insights into a person's physical and mental well-being. Irregular or abnormal breathing patterns can be a sign of serious health problems, so being able to monitor and detect these issues is important for timely diagnosis and treatment.

Wireless light-wave sensing (LWS) using infrared light is a promising approach for monitoring breathing without the need for wearable devices or invasive methods. This technology can provide a safe, discreet, and efficient way to track breathing without raising privacy concerns.

To make the respiration monitoring system effective, it needs to be trained on a variety of normal and abnormal breathing patterns. This allows the system to accurately identify breathing anomalies that may indicate health issues. The system must also be able to validate the collected data as a true breathing waveform, discarding any faulty data caused by external factors like movement or system malfunctions.

Technical Explanation

This study simulated normal and various types of abnormal respiration using a robot that mimics human breathing patterns. Time-series respiration data were then collected using infrared light-wave sensing technology. Three machine learning algorithms - decision tree, random forest, and XGBoost - were applied to detect breathing anomalies and identify faulty data.

The performance of these models was evaluated through cross-validation, assessing metrics like classification accuracy, precision, and recall. The random forest model achieved the highest classification accuracy of 96.75% with data collected at a 0.5m distance. In general, ensemble models like random forest and XGBoost performed better than a single model in classifying the data collected at multiple distances from the light-wave sensing setup.

Critical Analysis

The study provides a robust approach to training and validating a respiration monitoring system using simulated breathing data and advanced machine learning techniques. However, the research does not explicitly address the potential impact of individual variations in breathing patterns or the challenges of deploying the system in real-world scenarios with diverse populations.

Additionally, the study does not delve into the long-term reliability and robustness of the light-wave sensing technology, which could be affected by environmental factors or user behavior over extended periods of use. Further research is needed to validate the system's performance in real-world settings and address any potential limitations.

Conclusion

This study demonstrates the potential of wireless light-wave sensing for safe, discreet, and non-invasive monitoring of human breathing patterns. By leveraging machine learning algorithms to detect anomalies and validate the collected data, the proposed system shows promise in supporting early diagnosis and treatment of respiratory health issues. However, additional research is needed to address the challenges of individual variability and long-term reliability to ensure the system's effectiveness in real-world applications.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

Total Score

0

Noncontact Respiratory Anomaly Detection Using Infrared Light-Wave Sensing

Md Zobaer Islam, Brenden Martin, Carly Gotcher, Tyler Martinez, John F. O'Hara, Sabit Ekin

Human respiratory rate and its pattern convey essential information about the physical and psychological states of the subject. Abnormal breathing can indicate fatal health issues leading to further diagnosis and treatment. Wireless light-wave sensing (LWS) using incoherent infrared light shows promise in safe, discreet, efficient, and non-invasive human breathing monitoring without raising privacy concerns. The respiration monitoring system needs to be trained on different types of breathing patterns to identify breathing anomalies.The system must also validate the collected data as a breathing waveform, discarding any faulty data caused by external interruption, user movement, or system malfunction. To address these needs, this study simulated normal and different types of abnormal respiration using a robot that mimics human breathing patterns. Then, time-series respiration data were collected using infrared light-wave sensing technology. Three machine learning algorithms, decision tree, random forest and XGBoost, were applied to detect breathing anomalies and faulty data. Model performances were evaluated through cross-validation, assessing classification accuracy, precision and recall scores. The random forest model achieved the highest classification accuracy of 96.75% with data collected at a 0.5m distance. In general, ensemble models like random forest and XGBoost performed better than a single model in classifying the data collected at multiple distances from the light-wave sensing setup.

Read more

4/17/2024

Total Score

0

Respiratory Anomaly Detection using Reflected Infrared Light-wave Signals

Md Zobaer Islam, Brenden Martin, Carly Gotcher, Tyler Martinez, John F. O'Hara, Sabit Ekin

In this study, we present a non-contact respiratory anomaly detection method using incoherent light-wave signals reflected from the chest of a mechanical robot that can breathe like human beings. In comparison to existing radar and camera-based sensing systems for vitals monitoring, this technology uses only a low-cost ubiquitous infrared light source and sensor. This light-wave sensing system recognizes different breathing anomalies from the variations of light intensity reflected from the chest of the robot within a 0.5m-1.5m range with an average classification accuracy of up to 96.6% using machine learning.

Read more

6/19/2024

🏷️

Total Score

0

Non-Contact Breath Rate Classification Using SVM Model and mmWave Radar Sensor Data

Mohammad Wassaf Ali, Ayushi Gupta, Mujeev Khan, Mohd Wajid

This work presents the use of frequency modulated continuous wave (FMCW) radar technology combined with a machine learning model to differentiate between normal and abnormal breath rates. The proposed system non-contactly collects data using FMCW radar, which depends on breath rates. Various support vector machine kernels are used to classify the observed data into normal and abnormal states. Prolonged experiments show good accuracy in breath rate classification, confirming the model's efficacy. The best accuracy is 95 percent with the smallest number of support vectors in the case of the quadratic polynomial kernel.

Read more

7/19/2024

↗️

Total Score

0

Machine learning-based algorithms for at-home respiratory disease monitoring and respiratory assessment

Negar Orangi-Fard, Alexandru Bogdan, Hersh Sagreiya

Respiratory diseases impose a significant burden on global health, with current diagnostic and management practices primarily reliant on specialist clinical testing. This work aims to develop machine learning-based algorithms to facilitate at-home respiratory disease monitoring and assessment for patients undergoing continuous positive airway pressure (CPAP) therapy. Data were collected from 30 healthy adults, encompassing respiratory pressure, flow, and dynamic thoraco-abdominal circumferential measurements under three breathing conditions: normal, panting, and deep breathing. Various machine learning models, including the random forest classifier, logistic regression, and support vector machine (SVM), were trained to predict breathing types. The random forest classifier demonstrated the highest accuracy, particularly when incorporating breathing rate as a feature. These findings support the potential of AI-driven respiratory monitoring systems to transition respiratory assessments from clinical settings to home environments, enhancing accessibility and patient autonomy. Future work involves validating these models with larger, more diverse populations and exploring additional machine learning techniques.

Read more

9/6/2024