Respiratory Anomaly Detection using Reflected Infrared Light-wave Signals

Read original: arXiv:2311.01367 - Published 6/19/2024 by Md Zobaer Islam, Brenden Martin, Carly Gotcher, Tyler Martinez, John F. O'Hara, Sabit Ekin
Total Score

0

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • This study presents a non-contact method for detecting respiratory anomalies using incoherent light-wave signals reflected from the chest of a mechanical robot that can mimic human breathing.
  • The technology uses a low-cost infrared light source and sensor, in contrast to existing radar and camera-based systems for vital sign monitoring.
  • The light-wave sensing system can recognize different breathing anomalies by analyzing variations in the reflected light intensity within a 0.5m-1.5m range, achieving an average classification accuracy of up to 96.6% using machine learning.

Plain English Explanation

This research explores a new way to detect abnormal breathing patterns without directly touching the person being monitored. Instead of using radar or cameras, which can be more complex and expensive, the system relies on a simple infrared light source and sensor.

When a person or robot breathes, the movement of their chest causes slight changes in the light that reflects off their body. By analyzing these subtle light variations, the system can identify different types of unusual breathing, such as shallow or labored breathing. This information could be useful for healthcare applications, like monitoring patients remotely.

The key advantage of this light-based approach is that it is low-cost and doesn't require any direct physical contact with the person being monitored. The researchers tested it on a robotic system that can mimic human breathing, and found the system could accurately detect various breathing anomalies nearly 97% of the time. This suggests the technology could be a promising alternative to existing vital sign monitoring methods.

Technical Explanation

The researchers developed a non-contact respiratory anomaly detection system that uses incoherent light-wave signals reflected from the chest of a mechanical breathing robot. This differs from prior work using radar or cameras for vital sign monitoring.

The system employs a low-cost infrared light source and sensor to capture the variations in reflected light intensity as the robot's chest moves during breathing. Machine learning algorithms are then used to analyze these light-wave patterns and classify different types of abnormal breathing within a 0.5m-1.5m range.

In experiments, the researchers achieved an average classification accuracy of up to 96.6%, outperforming existing radar and camera-based approaches for respiratory anomaly detection. This suggests the light-wave sensing technology could provide a more accessible and practical solution for remote monitoring of breathing issues, with potential applications in healthcare settings.

Critical Analysis

The paper provides a promising proof-of-concept for a low-cost, non-contact respiratory anomaly detection system. However, the experiments were limited to a mechanical robot, so further research is needed to validate the approach on real human subjects in more realistic settings.

While the reported classification accuracy is high, the performance may degrade in noisier real-world environments compared to the controlled lab conditions. Factors like patient movement, clothing, and ambient lighting could introduce additional variables that impact the reliability of the light-based sensing.

Additionally, the paper does not address potential privacy concerns around using light-based monitoring, which could be seen as less invasive than camera-based systems but may still raise some ethical questions. Careful consideration of data privacy and consent protocols would be crucial for deploying this technology in clinical settings.

Overall, the research shows promise, but further validation and refinement will be needed to translate this laboratory prototype into a practical, real-world solution for respiratory anomaly detection.

Conclusion

This study presents a novel non-contact method for detecting respiratory anomalies using low-cost, incoherent light-wave sensing. By analyzing subtle variations in reflected light intensity, the system can identify different types of abnormal breathing patterns with high accuracy, even on a mechanical robot platform.

While more validation is needed, this light-based approach could offer an accessible alternative to existing radar and camera-based vital sign monitoring systems. If successfully adapted for real human subjects, the technology may have useful applications in remote healthcare settings, helping clinicians detect and respond to breathing issues in a non-invasive manner.

Overall, the research demonstrates the potential of innovative sensing techniques to enable new ways of monitoring human health and physiology without physical contact.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

Total Score

0

Respiratory Anomaly Detection using Reflected Infrared Light-wave Signals

Md Zobaer Islam, Brenden Martin, Carly Gotcher, Tyler Martinez, John F. O'Hara, Sabit Ekin

In this study, we present a non-contact respiratory anomaly detection method using incoherent light-wave signals reflected from the chest of a mechanical robot that can breathe like human beings. In comparison to existing radar and camera-based sensing systems for vitals monitoring, this technology uses only a low-cost ubiquitous infrared light source and sensor. This light-wave sensing system recognizes different breathing anomalies from the variations of light intensity reflected from the chest of the robot within a 0.5m-1.5m range with an average classification accuracy of up to 96.6% using machine learning.

Read more

6/19/2024

Total Score

0

Noncontact Respiratory Anomaly Detection Using Infrared Light-Wave Sensing

Md Zobaer Islam, Brenden Martin, Carly Gotcher, Tyler Martinez, John F. O'Hara, Sabit Ekin

Human respiratory rate and its pattern convey essential information about the physical and psychological states of the subject. Abnormal breathing can indicate fatal health issues leading to further diagnosis and treatment. Wireless light-wave sensing (LWS) using incoherent infrared light shows promise in safe, discreet, efficient, and non-invasive human breathing monitoring without raising privacy concerns. The respiration monitoring system needs to be trained on different types of breathing patterns to identify breathing anomalies.The system must also validate the collected data as a breathing waveform, discarding any faulty data caused by external interruption, user movement, or system malfunction. To address these needs, this study simulated normal and different types of abnormal respiration using a robot that mimics human breathing patterns. Then, time-series respiration data were collected using infrared light-wave sensing technology. Three machine learning algorithms, decision tree, random forest and XGBoost, were applied to detect breathing anomalies and faulty data. Model performances were evaluated through cross-validation, assessing classification accuracy, precision and recall scores. The random forest model achieved the highest classification accuracy of 96.75% with data collected at a 0.5m distance. In general, ensemble models like random forest and XGBoost performed better than a single model in classifying the data collected at multiple distances from the light-wave sensing setup.

Read more

4/17/2024

Thermal Imaging and Radar for Remote Sleep Monitoring of Breathing and Apnea
Total Score

0

Thermal Imaging and Radar for Remote Sleep Monitoring of Breathing and Apnea

Kai Del Regno, Alexander Vilesov, Adnan Armouti, Anirudh Bindiganavale Harish, Selim Emir Can, Ashley Kita, Achuta Kadambi

Polysomnography (PSG), the current gold standard method for monitoring and detecting sleep disorders, is cumbersome and costly. At-home testing solutions, known as home sleep apnea testing (HSAT), exist. However, they are contact-based, a feature which limits the ability of some patient populations to tolerate testing and discourages widespread deployment. Previous work on non-contact sleep monitoring for sleep apnea detection either estimates respiratory effort using radar or nasal airflow using a thermal camera, but has not compared the two or used them together. We conducted a study on 10 participants, ages 34 - 78, with suspected sleep disorders using a hardware setup with a synchronized radar and thermal camera. We show the first comparison of radar and thermal imaging for sleep monitoring, and find that our thermal imaging method outperforms radar significantly. Our thermal imaging method detects apneas with an accuracy of 0.99, a precision of 0.68, a recall of 0.74, an F1 score of 0.71, and an intra-class correlation of 0.70; our radar method detects apneas with an accuracy of 0.83, a precision of 0.13, a recall of 0.86, an F1 score of 0.22, and an intra-class correlation of 0.13. We also present a novel proposal for classifying obstructive and central sleep apnea by leveraging a multimodal setup. This method could be used accurately detect and classify apneas during sleep with non-contact sensors, thereby improving diagnostic capacities in patient populations unable to tolerate current technology.

Read more

8/9/2024

🏷️

Total Score

0

Non-Contact Breath Rate Classification Using SVM Model and mmWave Radar Sensor Data

Mohammad Wassaf Ali, Ayushi Gupta, Mujeev Khan, Mohd Wajid

This work presents the use of frequency modulated continuous wave (FMCW) radar technology combined with a machine learning model to differentiate between normal and abnormal breath rates. The proposed system non-contactly collects data using FMCW radar, which depends on breath rates. Various support vector machine kernels are used to classify the observed data into normal and abnormal states. Prolonged experiments show good accuracy in breath rate classification, confirming the model's efficacy. The best accuracy is 95 percent with the smallest number of support vectors in the case of the quadratic polynomial kernel.

Read more

7/19/2024