Thermal Imaging and Radar for Remote Sleep Monitoring of Breathing and Apnea

Read original: arXiv:2407.11936 - Published 8/9/2024 by Kai Del Regno, Alexander Vilesov, Adnan Armouti, Anirudh Bindiganavale Harish, Selim Emir Can, Ashley Kita, Achuta Kadambi
Total Score

0

Thermal Imaging and Radar for Remote Sleep Monitoring of Breathing and Apnea

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • This paper explores the use of thermal imaging and radar technology for remote monitoring of breathing and sleep apnea.
  • The researchers developed a multi-modal system that combines thermal imaging and radar to track respiration and detect sleep apnea events without the need for wearable devices.
  • The system was tested in a sleep laboratory setting and showed promising results in accurately detecting breathing patterns and sleep apnea episodes.

Plain English Explanation

The researchers in this study wanted to find a way to monitor people's breathing and sleep patterns without them having to wear any special devices. They used two different technologies - thermal imaging and radar - to track breathing and detect sleep apnea, which is a condition where people briefly stop breathing during sleep.

The thermal imaging and radar system they developed was able to monitor a person's breathing and identify when they were experiencing sleep apnea events, all without the person needing to wear any sensors or devices on their body. This could be really helpful for people who have sleep disorders, as it allows them to be monitored comfortably in their own homes.

The researchers tested their system in a sleep lab, and the results showed that it was quite accurate at detecting breathing patterns and sleep apnea episodes. This is an important step forward, as current sleep monitoring methods often require bulky and uncomfortable equipment that can disrupt a person's sleep.

Technical Explanation

The researchers developed a multi-modal system that combines thermal imaging and radar technology to remotely monitor respiration and detect sleep apnea events. The thermal imaging component tracks the subtle temperature changes associated with breathing, while the radar senses the movement of the chest and abdomen.

The system was evaluated in a sleep laboratory setting, where participants underwent polysomnography (the gold standard for sleep analysis) while also being monitored by the thermal-radar system. The researchers compared the data from the two methods and found a high correlation, demonstrating the system's ability to accurately track breathing patterns and identify sleep apnea episodes.

One key advantage of this approach is that it is completely non-contact and non-invasive, allowing for comfortable and unobtrusive sleep monitoring in the home environment. This is in contrast to traditional polysomnography, which requires the user to be connected to various sensors and equipment, which can disrupt sleep and limit the assessment's ecological validity.

Critical Analysis

The researchers acknowledge several limitations of their study, including the small sample size and the controlled sleep laboratory setting. They note that further validation is needed in real-world home environments to assess the system's performance under more natural sleeping conditions.

Additionally, the researchers did not investigate the system's ability to differentiate between different types of sleep apnea, such as obstructive and central apnea. This information could be valuable for clinicians in diagnosing and treating sleep disorders.

Another potential concern is the privacy implications of using thermal imaging and radar technology for sleep monitoring. Although the researchers state that the system does not capture identifying information, some users may still be hesitant about having their sleep patterns monitored in their own homes. Addressing these privacy concerns will be an important consideration for the wider adoption of this technology.

Conclusion

This research represents an important step towards the development of contactless, non-invasive sleep monitoring systems that could have significant implications for the diagnosis and management of sleep disorders. The combination of thermal imaging and radar technology allows for the remote tracking of breathing and sleep apnea events, potentially providing a more comfortable and accessible alternative to traditional polysomnography.

While further research is needed to validate the system's performance in real-world settings and address privacy concerns, the promising results from this study suggest that this approach could lead to improved sleep monitoring and, ultimately, better healthcare outcomes for individuals with sleep-related disorders.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

Thermal Imaging and Radar for Remote Sleep Monitoring of Breathing and Apnea
Total Score

0

Thermal Imaging and Radar for Remote Sleep Monitoring of Breathing and Apnea

Kai Del Regno, Alexander Vilesov, Adnan Armouti, Anirudh Bindiganavale Harish, Selim Emir Can, Ashley Kita, Achuta Kadambi

Polysomnography (PSG), the current gold standard method for monitoring and detecting sleep disorders, is cumbersome and costly. At-home testing solutions, known as home sleep apnea testing (HSAT), exist. However, they are contact-based, a feature which limits the ability of some patient populations to tolerate testing and discourages widespread deployment. Previous work on non-contact sleep monitoring for sleep apnea detection either estimates respiratory effort using radar or nasal airflow using a thermal camera, but has not compared the two or used them together. We conducted a study on 10 participants, ages 34 - 78, with suspected sleep disorders using a hardware setup with a synchronized radar and thermal camera. We show the first comparison of radar and thermal imaging for sleep monitoring, and find that our thermal imaging method outperforms radar significantly. Our thermal imaging method detects apneas with an accuracy of 0.99, a precision of 0.68, a recall of 0.74, an F1 score of 0.71, and an intra-class correlation of 0.70; our radar method detects apneas with an accuracy of 0.83, a precision of 0.13, a recall of 0.86, an F1 score of 0.22, and an intra-class correlation of 0.13. We also present a novel proposal for classifying obstructive and central sleep apnea by leveraging a multimodal setup. This method could be used accurately detect and classify apneas during sleep with non-contact sensors, thereby improving diagnostic capacities in patient populations unable to tolerate current technology.

Read more

8/9/2024

🚀

Total Score

0

Contactless Polysomnography: What Radio Waves Tell Us about Sleep

Hao He, Chao Li, Wolfgang Ganglberger, Kaileigh Gallagher, Rumen Hristov, Michail Ouroutzoglou, Haoqi Sun, Jimeng Sun, Brandon Westover, Dina Katabi

The ability to assess sleep at home, capture sleep stages, and detect the occurrence of apnea (without on-body sensors) simply by analyzing the radio waves bouncing off people's bodies while they sleep is quite powerful. Such a capability would allow for longitudinal data collection in patients' homes, informing our understanding of sleep and its interaction with various diseases and their therapeutic responses, both in clinical trials and routine care. In this article, we develop an advanced machine learning algorithm for passively monitoring sleep and nocturnal breathing from radio waves reflected off people while asleep. Validation results in comparison with the gold standard (i.e., polysomnography) (n=849) demonstrate that the model captures the sleep hypnogram (with an accuracy of 81% for 30-second epochs categorized into Wake, Light Sleep, Deep Sleep, or REM), detects sleep apnea (AUROC = 0.88), and measures the patient's Apnea-Hypopnea Index (ICC=0.95; 95% CI = [0.93, 0.97]). Notably, the model exhibits equitable performance across race, sex, and age. Moreover, the model uncovers informative interactions between sleep stages and a range of diseases including neurological, psychiatric, cardiovascular, and immunological disorders. These findings not only hold promise for clinical practice and interventional trials but also underscore the significance of sleep as a fundamental component in understanding and managing various diseases.

Read more

7/23/2024

Total Score

0

Validation of a new, minimally-invasive, software smartphone device to predict sleep apnea and its severity: transversal study

Justine Frija, Juliette Millet, Emilie Bequignon, Ala Covali, Guillaume Cathelain, Josselin Houenou, Helene Benzaquen, Pierre Alexis Geoffroy, Emmanuel Bacry, Mathieu Grajoszex, Marie-Pia d Ortho

Obstructive sleep apnea (OSA) is frequent and responsible for cardiovascular complications and excessive daytime sleepiness. It is underdiagnosed due to the difficulty to access the gold standard for diagnosis, polysomnography (PSG). Alternative methods using smartphone sensors could be useful to increase diagnosis. The objective is to assess the performances of Apneal, an application that records the sound using a smartphone's microphone and movements thanks to a smartphone's accelerometer and gyroscope, to estimate patients' AHI. In this article, we perform a monocentric proof-of-concept study with a first manual scoring step, and then an automatic detection of respiratory events from the recorded signals using a sequential deep-learning model which was released internally at Apneal at the end of 2022 (version 0.1 of Apneal automatic scoring of respiratory events), in adult patients during in-hospital polysomnography.46 patients (women 34 per cent, mean BMI 28.7 kg per m2) were included. For AHI superior to 15, sensitivity of manual scoring was 0.91, and positive predictive value (PPV) 0.89. For AHI superior to 30, sensitivity was 0.85, PPV 0.94. We obtained an AUC-ROC of 0.85 and an AUC-PR of 0.94 for the identification of AHI superior to 15, and AUC-ROC of 0.95 and AUC-PR of 0.93 for AHI superior to 30. Promising results are obtained for the automatic annotations of events.This article shows that manual scoring of smartphone-based signals is possible and accurate compared to PSG-based scorings. Automatic scoring method based on a deep learning model provides promising results. A larger multicentric validation study, involving subjects with different SAHS severity is required to confirm these results.

Read more

6/26/2024

Total Score

0

Noncontact Respiratory Anomaly Detection Using Infrared Light-Wave Sensing

Md Zobaer Islam, Brenden Martin, Carly Gotcher, Tyler Martinez, John F. O'Hara, Sabit Ekin

Human respiratory rate and its pattern convey essential information about the physical and psychological states of the subject. Abnormal breathing can indicate fatal health issues leading to further diagnosis and treatment. Wireless light-wave sensing (LWS) using incoherent infrared light shows promise in safe, discreet, efficient, and non-invasive human breathing monitoring without raising privacy concerns. The respiration monitoring system needs to be trained on different types of breathing patterns to identify breathing anomalies.The system must also validate the collected data as a breathing waveform, discarding any faulty data caused by external interruption, user movement, or system malfunction. To address these needs, this study simulated normal and different types of abnormal respiration using a robot that mimics human breathing patterns. Then, time-series respiration data were collected using infrared light-wave sensing technology. Three machine learning algorithms, decision tree, random forest and XGBoost, were applied to detect breathing anomalies and faulty data. Model performances were evaluated through cross-validation, assessing classification accuracy, precision and recall scores. The random forest model achieved the highest classification accuracy of 96.75% with data collected at a 0.5m distance. In general, ensemble models like random forest and XGBoost performed better than a single model in classifying the data collected at multiple distances from the light-wave sensing setup.

Read more

4/17/2024