Study of MRI-compatible Notched Plastic Ultrasonic Stator with FEM Simulation and Holography Validation

Read original: arXiv:2408.08528 - Published 8/19/2024 by Zhanyue Zhao, Haimi Tang, Paulo Carvalho, Cosme Furlong, Gregory S. Fischer
Total Score

0

Study of MRI-compatible Notched Plastic Ultrasonic Stator with FEM Simulation and Holography Validation

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • MRI-compatible ultrasonic actuator made from notched plastic
  • Combines finite element modeling (FEM) and digital holographic interferometry (DHI) for analysis and validation
  • Potential applications in medical robotics and devices that require MRI compatibility

Plain English Explanation

The paper describes the development and analysis of an MRI-compatible ultrasonic actuator made from notched plastic. This type of actuator could be useful for medical robots and devices that need to operate safely within the strong magnetic fields of MRI machines.

The researchers used finite element modeling (FEM) to simulate the behavior of the plastic ultrasonic stator, which is the stationary part of the actuator. They also validated the model's accuracy through digital holographic interferometry (DHI), a technique that visualizes the vibration patterns of the stator.

By combining computational modeling and experimental validation, the team was able to optimize the design of this MRI-compatible actuator and demonstrate its potential for use in medical robotics and devices that need to operate in the presence of strong magnetic fields.

Technical Explanation

The researchers developed an MRI-compatible ultrasonic actuator made from a notched plastic stator. They used finite element modeling (FEM) to simulate the dynamic behavior of the plastic stator, including its vibration patterns and deformations.

To validate the FEM model, the team employed digital holographic interferometry (DHI), an experimental technique that visualizes the full-field vibration of the stator. By comparing the simulation results to the DHI measurements, the researchers were able to ensure the accuracy of their FEM model.

The combination of computational modeling and experimental validation allowed the researchers to optimize the design of the MRI-compatible ultrasonic actuator, exploring factors such as the geometry of the notched plastic and the drive frequency to achieve the desired actuator performance.

Critical Analysis

The paper provides a thorough and well-designed approach to the development and analysis of an MRI-compatible ultrasonic actuator. The combination of FEM simulation and DHI validation is a robust methodology that helps ensure the accuracy of the computational model and the reliability of the actuator design.

However, the paper does not extensively discuss the practical limitations or challenges of implementing this type of actuator in real-world medical applications. For example, the long-term durability and reliability of the plastic stator in the MRI environment, or the integration of the actuator into larger robotic systems, are not addressed in depth.

Additionally, the paper could benefit from a more rigorous comparison of the performance and characteristics of the plastic ultrasonic actuator to other MRI-compatible actuation technologies, such as pneumatic or hydraulic systems. This would help readers better understand the unique advantages and trade-offs of the proposed solution.

Conclusion

This paper presents a comprehensive study of an MRI-compatible ultrasonic actuator made from a notched plastic stator. By leveraging finite element modeling and digital holographic interferometry, the researchers were able to optimize the design of this actuator and demonstrate its potential for use in medical robotics and devices that need to operate in the presence of strong magnetic fields.

The combination of computational modeling and experimental validation is a robust approach that could be applied to the development of other MRI-compatible actuators and medical devices. As the field of medical robotics continues to evolve, innovations like this MRI-compatible ultrasonic actuator will play an important role in enabling new capabilities and applications.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

Study of MRI-compatible Notched Plastic Ultrasonic Stator with FEM Simulation and Holography Validation
Total Score

0

Study of MRI-compatible Notched Plastic Ultrasonic Stator with FEM Simulation and Holography Validation

Zhanyue Zhao, Haimi Tang, Paulo Carvalho, Cosme Furlong, Gregory S. Fischer

Intra-operative image guidance using magnetic resonance imaging (MRI) can significantly enhance the precision of surgical procedures, such as deep brain tumor ablation. However, the powerful magnetic fields and limited space within an MRI scanner require the use of robotic devices to aid surgeons. Piezoelectric motors are commonly utilized to drive these robots, with piezoelectric ultrasonic motors being particularly notable. These motors consist of a piezoelectric ring stator that is bonded to a rotor through frictional coupling. When the stator is excited at specific frequencies, it generates distinctive mode shapes with surface waves that exhibit both in-plane and out-of-plane displacement, leading to the rotation of the rotor. In this study, we continue our previous work and refine the motor design and performance, we combine finite element modeling (FEM) with stroboscopic and time-averaged digital holography to validate a further plastic-based ultrasonic motor with better rotary performance.

Read more

8/19/2024

Design and Characterization of MRI-compatible Plastic Ultrasonic Motor
Total Score

0

Design and Characterization of MRI-compatible Plastic Ultrasonic Motor

Zhanyue Zhao, Charles Bales, Gregory Fischer

Precise surgical procedures may benefit from intra-operative image guidance using magnetic resonance imaging (MRI). However, the MRI's strong magnetic fields, fast switching gradients, and constrained space pose the need for an MR-guided robotic system to assist the surgeon. Piezoelectric actuators can be used in an MRI environment by utilizing the inverse piezoelectric effect for different application purposes. Piezoelectric ultrasonic motor (USM) is one type of MRI-compatible actuator that can actuate these robots with fast response times, compactness, and simple configuration. Although the piezoelectric motors are mostly made of nonferromagnetic material, the generation of eddy currents due to the MRI's gradient fields can lead to magnetic field distortions causing image artifacts. Motor vibrations due to interactions between the MRI's magnetic fields and those generated by the eddy currents can further degrade image quality by causing image artifacts. In this work, a plastic piezoelectric ultrasonic (USM) motor with more degree of MRI compatibility was developed and induced with preliminary optimization. Multiple parameters, namely teeth number, notch size, edge bevel or straight, and surface finish level parameters were used versus the prepressure for the experiment, and the results suggested that using 48 teeth, thin teeth notch with 0.39mm, beveled edge and a surface finish using grit number of approximate 1000 sandpaper performed a better output both in rotary speed and torque. Under this combination, the highest speed reached up to 436.6665rpm when the prepressure was low, and the highest torque reached up to 0.0348Nm when the prepressure was approximately 500g.

Read more

9/9/2024

Characterization and Design of A Hollow Cylindrical Ultrasonic Motor
Total Score

0

Characterization and Design of A Hollow Cylindrical Ultrasonic Motor

Zhanyue Zhao, Yang Wang, Charles Bales, Daniel Ruiz-Cadalso, Howard Zheng, Cosme Furlong-Vazquez, Gregory Fischer

Piezoelectric ultrasonic motors perform the advantages of compact design, faster reaction time, and simpler setup compared to other motion units such as pneumatic and hydraulic motors, especially its non-ferromagnetic property makes it a perfect match in MRI-compatible robotics systems compared to traditional DC motors. Hollow shaft motors address the advantages of being lightweight and comparable to solid shafts of the same diameter, low rotational inertia, high tolerance to rotational imbalance due to low weight, and tolerance to high temperature due to low specific mass. This article presents a prototype of a hollow cylindrical ultrasonic motor (HCM) to perform direct drive, eliminate mechanical non-linearity, and reduce the size and complexity of the actuator or end effector assembly. Two equivalent HCMs are presented in this work, and under 50g prepressure on the rotor, it performed 383.3333rpm rotation speed and 57.3504mNm torque output when applying 282$V_{pp}$ driving voltage.

Read more

9/14/2024

🏋️

Total Score

0

Design and Control of a Compact Series Elastic Actuator Module for Robots in MRI Scanners

Binghan He, Naichen Zhao, David Y. Guo, Charles H. Paxson, Ronald S. Fearing

In this study, we introduce a novel MRI-compatible rotary series elastic actuator module utilizing velocity-sourced ultrasonic motors for force-controlled robots operating within MRI scanners. Unlike previous MRI-compatible SEA designs, our module incorporates a transmission force sensing series elastic actuator structure, with four off-the-shelf compression springs strategically placed between the gearbox housing and the motor housing. This design features a compact size, thus expanding possibilities for a wider range of MRI robotic applications. To achieve precise torque control, we develop a controller that incorporates a disturbance observer tailored for velocity-sourced motors. This controller enhances the robustness of torque control in our actuator module, even in the presence of varying external impedance, thereby augmenting its suitability for MRI-guided medical interventions. Experimental validation demonstrates the actuator's torque control performance in both 3 Tesla MRI and non-MRI environments, achieving a settling time of 0.1 seconds and a steady-state error within 2% of its maximum output torque. Notably, our force controller exhibits consistent performance across low and high external impedance scenarios, in contrast to conventional controllers for velocity-sourced series elastic actuators, which struggle with steady-state performance under low external impedance conditions.