Self-Supervised Modality-Agnostic Pre-Training of Swin Transformers

Read original: arXiv:2405.12781 - Published 5/22/2024 by Abhiroop Talasila, Maitreya Maity, U. Deva Priyakumar
Total Score

0

🛠️

Sign in to get full access

or

If you already have an account, we'll log you in

Overview

  • Unsupervised pre-training has led to significant advancements in various domains
  • However, the susceptibility to domain shift, where pre-training data distribution differs from fine-tuning, poses a challenge
  • This paper proposes a solution called SwinFUSE (Swin Multi-Modal Fusion for UnSupervised Enhancement) to address this issue

Plain English Explanation

SwinFUSE is a model that aims to overcome the challenge of domain shift in pre-training. Domain shift occurs when the data used for pre-training (initial training) is different from the data used for fine-tuning (further training on a specific task).

To address this, SwinFUSE learns from multiple medical imaging modalities, namely Computed Tomography (CT) and Magnetic Resonance Imaging (MRI), during pre-training. This allows the model to develop complementary feature representations that can better adapt to different data distributions.

Additionally, SwinFUSE includes a domain-invariance module (DIM) that helps the model focus on the most relevant input regions, enhancing its adaptability to different domains.

Remarkably, SwinFUSE exhibits strong generalizability, performing well on tasks beyond what it was initially pre-trained on. This suggests that the model has learned versatile and transferable features, making it a practical and applicable solution for real-world scenarios.

Technical Explanation

SwinFUSE is built upon the Swin Transformer architecture, which has shown promising results in various domains. The key innovations of SwinFUSE are:

  1. Multi-Modal Pre-Training: SwinFUSE learns from both CT and MRI data during the pre-training stage, allowing it to develop complementary feature representations that can better adapt to different medical imaging modalities.

  2. Domain-Invariance Module (DIM): SwinFUSE includes a DIM that effectively highlights the salient input regions, enhancing the model's adaptability to different data distributions.

  3. Generalizability: SwinFUSE exhibits remarkable generalizability, surpassing the confines of the tasks it was initially pre-trained on. This suggests the model has learned versatile and transferable features.

The researchers evaluated SwinFUSE on two publicly available 3D segmentation datasets. Their experiments showed a modest 1-2% performance trade-off compared to single-modality models, but a significant out-performance of up to 27% on out-of-distribution modality. This substantial improvement highlights the practical relevance and real-world applicability of the proposed approach.

Critical Analysis

The paper acknowledges that there is a modest performance trade-off when using SwinFUSE compared to single-modality models. This is a reasonable tradeoff, as the primary goal of SwinFUSE is to address the domain shift problem and enhance generalizability, rather than optimize for single-task performance.

One potential area for further research could be investigating the impact of different medical imaging modalities on the model's performance and feature representations. It would be interesting to see how the model's behavior and transferability vary when trained on a wider range of modalities, such as Positron Emission Tomography (PET) or Ultrasound.

Additionally, the paper could have explored the model's performance on a more diverse set of tasks, beyond just 3D segmentation, to further demonstrate its generalizability and versatility. Evaluating SwinFUSE on multimodal information interaction for medical image segmentation tasks could provide valuable insights.

Overall, the SwinFUSE approach presents a promising solution to the domain shift problem in unsupervised pre-training, with the potential for significant real-world impact in the medical imaging domain.

Conclusion

SwinFUSE, a Swin Transformer-based model, addresses the challenge of domain shift in unsupervised pre-training by learning from multiple medical imaging modalities. Its key innovations include multi-modal pre-training, a domain-invariance module, and remarkable generalizability.

The experiments demonstrate SwinFUSE's ability to outperform single-modality models on out-of-distribution data, highlighting its practical relevance and potential for real-world application in the medical imaging field. While there is a modest performance trade-off, the model's enhanced adaptability and transferability make it a compelling solution for overcoming the domain shift problem in unsupervised pre-training.



This summary was produced with help from an AI and may contain inaccuracies - check out the links to read the original source documents!

Follow @aimodelsfyi on 𝕏 →

Related Papers

🛠️

Total Score

0

Self-Supervised Modality-Agnostic Pre-Training of Swin Transformers

Abhiroop Talasila, Maitreya Maity, U. Deva Priyakumar

Unsupervised pre-training has emerged as a transformative paradigm, displaying remarkable advancements in various domains. However, the susceptibility to domain shift, where pre-training data distribution differs from fine-tuning, poses a significant obstacle. To address this, we augment the Swin Transformer to learn from different medical imaging modalities, enhancing downstream performance. Our model, dubbed SwinFUSE (Swin Multi-Modal Fusion for UnSupervised Enhancement), offers three key advantages: (i) it learns from both Computed Tomography (CT) and Magnetic Resonance Images (MRI) during pre-training, resulting in complementary feature representations; (ii) a domain-invariance module (DIM) that effectively highlights salient input regions, enhancing adaptability; (iii) exhibits remarkable generalizability, surpassing the confines of tasks it was initially pre-trained on. Our experiments on two publicly available 3D segmentation datasets show a modest 1-2% performance trade-off compared to single-modality models, yet significant out-performance of up to 27% on out-of-distribution modality. This substantial improvement underscores our proposed approach's practical relevance and real-world applicability. Code is available at: https://github.com/devalab/SwinFUSE

Read more

5/22/2024

Self-supervised learning improves robustness of deep learning lung tumor segmentation to CT imaging differences
Total Score

0

Self-supervised learning improves robustness of deep learning lung tumor segmentation to CT imaging differences

Jue Jiang, Aneesh Rangnekar, Harini Veeraraghavan

Self-supervised learning (SSL) is an approach to extract useful feature representations from unlabeled data, and enable fine-tuning on downstream tasks with limited labeled examples. Self-pretraining is a SSL approach that uses the curated task dataset for both pretraining the networks and fine-tuning them. Availability of large, diverse, and uncurated public medical image sets provides the opportunity to apply SSL in the wild and potentially extract features robust to imaging variations. However, the benefit of wild- vs self-pretraining has not been studied for medical image analysis. In this paper, we compare robustness of wild versus self-pretrained transformer (vision transformer [ViT] and hierarchical shifted window [Swin]) models to computed tomography (CT) imaging differences for non-small cell lung cancer (NSCLC) segmentation. Wild-pretrained Swin models outperformed self-pretrained Swin for the various imaging acquisitions. ViT resulted in similar accuracy for both wild- and self-pretrained models. Masked image prediction pretext task that forces networks to learn the local structure resulted in higher accuracy compared to contrastive task that models global image information. Wild-pretrained models resulted in higher feature reuse at the lower level layers and feature differentiation close to output layer after fine-tuning. Hence, we conclude: Wild-pretrained networks were more robust to analyzed CT imaging differences for lung tumor segmentation than self-pretrained methods. Swin architecture benefited from such pretraining more than ViT.

Read more

5/15/2024

Swin SMT: Global Sequential Modeling in 3D Medical Image Segmentation
Total Score

0

Swin SMT: Global Sequential Modeling in 3D Medical Image Segmentation

Szymon P{l}otka, Maciej Chrabaszcz, Przemyslaw Biecek

Recent advances in Vision Transformers (ViTs) have significantly enhanced medical image segmentation by facilitating the learning of global relationships. However, these methods face a notable challenge in capturing diverse local and global long-range sequential feature representations, particularly evident in whole-body CT (WBCT) scans. To overcome this limitation, we introduce Swin Soft Mixture Transformer (Swin SMT), a novel architecture based on Swin UNETR. This model incorporates a Soft Mixture-of-Experts (Soft MoE) to effectively handle complex and diverse long-range dependencies. The use of Soft MoE allows for scaling up model parameters maintaining a balance between computational complexity and segmentation performance in both training and inference modes. We evaluate Swin SMT on the publicly available TotalSegmentator-V2 dataset, which includes 117 major anatomical structures in WBCT images. Comprehensive experimental results demonstrate that Swin SMT outperforms several state-of-the-art methods in 3D anatomical structure segmentation, achieving an average Dice Similarity Coefficient of 85.09%. The code and pre-trained weights of Swin SMT are publicly available at https://github.com/MI2DataLab/SwinSMT.

Read more

7/11/2024

📈

Total Score

0

Enhancing 3D Transformer Segmentation Model for Medical Image with Token-level Representation Learning

Xinrong Hu, Dewen Zeng, Yawen Wu, Xueyang Li, Yiyu Shi

In the field of medical images, although various works find Swin Transformer has promising effectiveness on pixelwise dense prediction, whether pre-training these models without using extra dataset can further boost the performance for the downstream semantic segmentation remains unexplored.Applications of previous representation learning methods are hindered by the limited number of 3D volumes and high computational cost. In addition, most of pretext tasks designed specifically for Transformer are not applicable to hierarchical structure of Swin Transformer. Thus, this work proposes a token-level representation learning loss that maximizes agreement between token embeddings from different augmented views individually instead of volume-level global features. Moreover, we identify a potential representation collapse exclusively caused by this new loss. To prevent collapse, we invent a simple rotate-and-restore mechanism, which rotates and flips one augmented view of input volume, and later restores the order of tokens in the feature maps. We also modify the contrastive loss to address the discrimination between tokens at the same position but from different volumes. We test our pre-training scheme on two public medical segmentation datasets, and the results on the downstream segmentation task show more improvement of our methods than other state-of-the-art pre-trainig methods.

Read more

8/13/2024